Electrician fitting a bonding clamp to a gas pipe beside a water heater.
HomeService AreasWesley ChapelElectrical Grounding and Bonding

Electrical Grounding and Bonding in Wesley Chapel, FL

Gas Pipe, Water Line, and Pool Bonds Tied to the Home's Grounding|Licensed & Insured, EC13011268

Kennedy Electric restores the bonds that tie a Wesley Chapel home's metal piping to its grounding, wherever a later job left one loose or missing, or none was ever fitted. In a house heated by gas, that includes the gas piping, whose bond can come through a grounded appliance circuit or a clamp, and every other metal system on the lot is traced back to the same grounding.

Say whether the house is heated by gas.

Licensed & Insured · Florida Certified Electrical Contractor EC13011268★ Google RatedNo trip charge, no service fee

Call (352) 251-2795, Monday through Friday, 8 a.m. to 4 p.m., or send a request online. Calls after hours are returned the next business day.

Metal to Bond in a Wesley Chapel House

At a glance

Metal to Bond in a Wesley Chapel House

Nearly one in five occupied homes in Wesley Chapel heat with gas, by census estimates, most of them from a utility main and a few hundred from bottled or tank gas. Whichever way the gas arrives, the house has metal gas piping inside it, and the electrical code expects that piping to be bonded to the home's grounding.

Summer lightning reaches Pasco on most days of the season, which the county's hazard mitigation plan ties to daily heating and moisture in the air. A nearby strike can briefly raise the voltage on a line, a pipe, or the ground. Bonding isn't lightning protection, and it promises nothing about a strike. It keeps the home's metal piping at the voltage of its grounding.

Close to 20,000 of the town's homes date from 2000 onward, again by estimate. In houses that young, the water lines inside can be plastic, which carries no current, and that can leave the gas piping and any pool as the metal the bonding has to reach.

What to Gather for a Bonding Check

How it runs

What to Gather for a Bonding Check

  1. 1

    Every metal line that enters the house

    Note where the gas comes in, from a meter on an outside wall or a tank in the yard, and where the water main enters. Add the pool if the lot has one, and any outdoor kitchen or fire feature with a gas line of its own.

  2. 2

    Photos at the water heater and the furnace

    Pipes near these appliances can carry a bonding clamp, or show where one used to sit. Those photos show what piping the house has, and one of the panel with its door swung open adds the grounding side.

  3. 3

    Which fixes belong to another trade

    Repairing or replacing gas pipe is a gas contractor's work, and rerouting water lines is a plumber's. The clamp, the bonding wire, and its connection back to the grounding are the electrical side, and that's the part we correct.

  4. 4

    A permit for new grounding conductors

    Pasco's under-$7,500 exemption for single-family homes names electrical work as an exception, so it still takes a permit. That covers the electrical side of a correction, such as a new grounding conductor or a change at the service, and the county inspects it.

What we cover

Bonding Points Around the House

Gas piping and how it's bonded

Inside a gas-heated house, metal pipe runs from where the gas enters to the furnace, the water heater, and any gas range or dryer. Rigid gas pipe counts as bonded under Florida's fuel gas code where it feeds an appliance on a grounded circuit, so the check confirms that circuit's grounding holds. Where a clamp is fitted, usually on a rigid section near the entry point, it and its copper wire back to the grounding are checked as well.

The water line and the water heater jumper

Copper or other metal pipe still turns up around the water heater or in a manifold, and each metal section is checked for whether it needs a bond. On metal supply pipe, a jumper is often fitted across the water heater so the bond carries past its fittings.

The pool's bonding grid

The pool's bonding grid ties the steel in the shell, the deck around the water, the light niches, and the pump and heater on the pad together, so all of it sits at one voltage. A rebuilt deck, a pad moved for a new heater, or a light changed out can leave a bond wire cut or unattached at that spot.

Grounding at the meter wall

Every bond above ties into the home's grounding, which meets the earth at the service. Outside at the meter wall, a grounding wire leads down to a rod, and in many newer houses it can also connect to steel in the concrete footing. A clamp, rod, or wire found damaged there is corrected along with the bonds.

Pricing

Rates for Grounding Visits and Bonding Fixes

01

Repair and troubleshooting visits are billed by the hour from arrival: $100 residential, $150 commercial, one-hour minimum, then half-hour increments, plus materials. No trip charge and no service fee. No hidden fees: the 3.5% surcharge on card and ACH payments is listed in our terms.

02

Finding a missing or broken bond is troubleshooting, so the hourly terms above apply to a grounding visit.

03

Custom homes and large or multi-phase projects are estimated as soon as we can, or on the timeline your project sets.

04

We don't do upfront pricing. No job has a standard price with us: each one is tailored to the property and the work you've asked for, and priced once we've seen it.

We offer free estimates on installs, upgrades, and replacements in our service area. Estimates aren't free when the job needs troubleshooting or testing to price, falls after hours or outside our service area, needs several meetings to gather information, or is new construction or a custom remodel with multi-party walk-throughs. For most jobs, estimates arrive by email by the end of the next business day, and quotes are good for 30 days.

Our warranty

05

If something we installed fails because of our workmanship within 30 days of completion, we waive the hourly labor to put it right. Materials Kennedy Electric purchases for your job carry the manufacturer's one-year warranty. To replace defective materials we supplied, or materials damaged by storm, flood, fire, or other acts of God, we charge a reduced warranty labor rate of $50 an hour residential and $75 an hour commercial. The warranty does not cover materials not purchased by Kennedy Electric, work performed by the customer, or materials the customer purchased or damaged. Our warranty terms are printed on the estimate, the invoice, and the receipt, and the product boxes stay with you so you can register each product with its manufacturer.

Common questions

Bonding Answers for Wesley Chapel Gas and Pool Homes

Our Wesley Chapel outdoor kitchen has a gas grill piped from the house. Does that line need a bond of its own?

Usually not, if metal pipe runs to it unbroken from the house's gas system, since a bond on that system reaches every metal run joined to it. A grill on a tank of its own isn't part of the house's gas piping.

We're replacing the gas water heater in our Wesley Chapel house with an electric one. What happens to the bonding?

That depends on whether a clamp was fitted, and where. If it was on the water heater's gas line and the gas contractor caps that line, the bond can move to piping that stays in service, such as the line to the furnace or the range. If the house gives up gas entirely and the piping comes out, there's no gas bond left to keep.

Our propane supplier swapped the tank in our Wesley Chapel yard. Does the bonding need to be redone?

Not because of the tank alone. The bond sits on the metal gas piping at the house, which a tank swap doesn't usually touch. If piping was replaced where the line enters, or a clamp was knocked during the work, that's the point to have it looked at. The tank and its fittings are for the gas trade, and we don't touch them.

If a neutral wire touches a ground wire somewhere in the house, will a breaker trip?

A standard breaker won't, which is how the fault goes unnoticed. Neutral and ground are meant to meet at one point only, in the service equipment. Past that point, the contact overloads nothing, so the breaker holds and the lights keep working, while part of the circuit's return current travels on the grounding wires and can reach metal bonded to them, piping included. A GFCI or many arc-fault breakers react differently: a neutral touching ground beyond one of them makes it trip.

We're finishing the garage walls in our Wesley Chapel house. Can the bonding clamp go behind the drywall?

It shouldn't be sealed in. A clamp at a water pipe that serves as an electrode generally has to stay accessible under the electrical code, and a gas bond is easier to check when it stays in view. An access panel in the new wall keeps either one reachable.
Dedicated appliance circuits in Wesley Chapel

Reviews

Homeowners Report Back on Kennedy Electric

Straight from Google, in our customers' own words.

Google reviews widget
Have the Bonds Checked at Your Wesley Chapel Home

Request service

Have the Bonds Checked at Your Wesley Chapel Home

Send what you gathered for the check, photos included. Our office will reach you during business hours.

Kennedy Electric
1160 Ponce De Leon Blvd, Brooksville, FL 34601
Monday through Friday, 8 a.m. to 4 p.m.
Licensed & Insured · Florida Certified Electrical Contractor EC13011268
Serving Citrus, Hernando, and Pasco Counties, and nearby Sumter County.
Property type*
Best way to reach you*

Related services

The service

Part of

Where we work