HomeElectrical Panel RepairGrounding & Bonding

Grounding and Bonding Repair in Brooksville, FL

Ground Rods and Grounding Conductors|Bonding of Pipes and Metal|Licensed & Insured, EC13011268

A tingle, a report, or new work: let us know what prompted the call.

Licensed & Insured · Florida Certified Electrical Contractor EC13011268★ Google RatedBilled from arrival, no trip charge
Grounding electrode conductor and ground rod clamp checked by Kennedy Electric in Hernando County, FL.
  • Ground rods and clamps. Driven, replaced, or reconnected.
  • Bonding restored. Water piping, gas piping, and panel connections.

Grounding and bonding are the parts of your electrical system you don't see, and the ones that decide what happens when something goes wrong: whether a fault trips the breaker or leaves metal in the house carrying voltage.

We find what's loose, missing, or wired the wrong way, from the rods outside to the connections inside the panel, and correct it.

Call (352) 251-2795, Monday through Friday, 8 a.m. to 4 p.m., or send a request online. Calls after hours are returned the next business day.

Grounding and Bonding, explained

Two Jobs That Sound Alike and Aren't

01

Grounding: a connection to the earth

Grounding ties your electrical system to the earth through a grounding electrode system: ground rods driven beside the house, and in some homes, a metal water pipe or the steel in the foundation. It holds the system at a steady voltage and gives surges from outside, including the power company's lines, a path into the ground.

Surge protection depends on this work: a whole-house surge device can only send excess voltage where the grounding allows it.

02

Bonding and the equipment ground

Bonding ties the metal parts of the system together so they sit at one voltage: boxes, conduit, metal water and gas piping. The equipment grounding conductor, the wire that runs to each outlet's third prong, carries fault current back to the panel, so if a hot wire touches something metal, the breaker trips at once. The earth is a poor path for that job, which is why a ground rod on its own won't trip a breaker.

03

If a faucet, appliance, or rail gives you a tingle

Stop touching it and keep others away from it. If you can reach the panel without touching that metal, turn off the breaker for that appliance or area, then call us. Call 911 if anyone is hurt.

Kennedy Electric electrician testing a circuit with a multimeter

How a Grounding job runs

Tracing the System From Rod to Panel

  1. 1

    1. What prompted the call

    A tingle, an inspection or evaluation report, repiping, a remodel, or new equipment such as a surge device or an EV charger. Send the report if there is one.

  2. 2

    2. Outside at the service

    The grounding conductor is followed from the meter and panel to the rods, and the clamps and connections are checked.

  3. 3

    3. Inside the panels

    The main bonding connection, the separation of neutral and ground in any subpanel, and the bonding to water and gas piping.

  4. 4

    4. What we found, and the fix

    You see what's missing or faulty, and you get a written estimate where the fix is more than the visit covers.

  5. 5

    5. Corrections

    Rods driven, clamps and conductors replaced, bonding jumpers added, and panel connections corrected.

What we correct

Grounding Faults and How They're Fixed

What we findWhy it mattersThe correction
Corroded or missing ground rod clampThe house loses its earth connectionNew listed clamp, or a new rod
Cut or damaged grounding conductorThe rods are cut off from the panelConductor replaced and protected
No rod, or only one where more are neededGrounding falls short of codeRods driven and connected
Neutral and ground joined in a subpanelCurrent can flow on bare metalSeparated and correctly bonded
No bonding to water or gas pipingPiping could carry voltage in a faultBonding jumper installed
No service disconnectNo single shut-off for the houseQuoted as a service change

Billing and estimates

Paying for Grounding Work

01

Repair and troubleshooting visits are billed by the hour from arrival: $100 residential, $150 commercial, one-hour minimum, then half-hour increments, plus materials. No trip charge and no service fee. No hidden fees: the 3.5% surcharge on card and ACH payments is listed in our terms.

02

We don't do upfront pricing. No job has a standard price with us: each one is tailored to the property and the work you've asked for, and priced once we've seen it.

We offer free estimates on installs, upgrades, and replacements in our service area. Estimates aren't free when the job needs troubleshooting or testing to price, falls after hours or outside our service area, needs several meetings to gather information, or is new construction or a custom remodel with multi-party walk-throughs. For most jobs, estimates arrive by email by the end of the next business day, and quotes are good for 30 days.

03

Custom homes and large or multi-phase projects are estimated as soon as we can, or on the timeline your project sets.

Our warranty

04

If something we installed fails because of our workmanship within 30 days of completion, we waive the hourly labor to put it right. Materials Kennedy Electric purchases for your job carry the manufacturer's one-year warranty. To replace defective materials we supplied, or materials damaged by storm, flood, fire, or other acts of God, we charge a reduced warranty labor rate of $50 an hour residential and $75 an hour commercial. The warranty does not cover materials not purchased by Kennedy Electric, work performed by the customer, or materials the customer purchased or damaged. Our warranty terms are printed on the estimate, the invoice, and the receipt, and the product boxes stay with you so you can register each product with its manufacturer.

Real customer stories

Hear It From Our Customers

Straight from Google, in our customers' own words.

Google reviews widget · live from GBP

Frequently asked Questions

Grounding Questions We Hear

Does a three-prong outlet mean my house is grounded?

Not by itself. The third slot is only grounded if a ground wire is connected behind it. A plug-in tester gives a first answer; an electrician can confirm the whole path back to the panel.

My plumber replaced our water pipes with PEX. Does that affect grounding?

It can. In some homes, the metal water line was part of the grounding electrode system, and plastic pipe doesn't conduct. Have the grounding checked after a repipe, and any metal piping that remains still needs bonding.

Do flexible gas lines need bonding?

Corrugated stainless-steel gas tubing, such as the yellow-jacketed kind, comes with bonding requirements from its manufacturers. If your home has it and you can't find a bonding clamp and wire near where it starts, ask us to check.

Is a ground rod replaced when the panel is replaced?

When a service is replaced, the inspector will expect its grounding and bonding brought up to the electrical code. Any rods, clamps, or conductors needed are part of the replacement estimate.

Contact us

Have Your Grounding Checked

Tell us what prompted the call, and send any inspection or evaluation report and a photo of the panel. We'll get back to you during business hours.