Man using a clamp meter on an outlet on a green wall

Pool & Spa Wiring in Bayonet Point, FL

Pool Lights, Pads, and Hot Tubs Behind the House|Licensed & Insured, EC13011268

At Bayonet Point homes, Kennedy Electric wires pools, hot tubs, and their equipment. Where a screened lanai backs onto the house, the work begins at that back wall, then follows the circuit out to the pump, the heater, and the pool light.

Say whether it's a pool, a hot tub, or both, and where on the lot it sits.

Licensed & Insured · Florida Certified Electrical Contractor EC13011268★ Google RatedFree estimate on new equipment wiring

Call (352) 251-2795, Monday through Friday, 8 a.m. to 4 p.m., or send a request online. Calls after hours are returned the next business day.

Electrician (Kennedy shirt) at an open exterior junction box

At a glance

Pools Under a Screen Roof, Hot Tubs on the Lanai

Beacon Woods' deed restrictions govern where a pool and its wiring can be located. They rule out above-ground pools and allow an in-ground pool only behind the house, within a screened enclosure with a screened roof attached to the home, kept 5 feet off the rear and side lot lines. A hot tub, under the same restrictions, may be placed inside a screened porch, lanai, or existing pool enclosure, and never on the side or front of the home.

The association's guidelines add that what goes onto a screened lanai sits outside its architectural review, while noting that state law and county rules still apply. On the county's side, Pasco wants the pool equipment's location and setbacks shown on the site plan, the flood zone marked, and the dividing line shown where a lot sits in two zones. On a lot split that way, the drawing shows which zone the pad sits in before any of its wiring goes in.

Electrician (Kennedy shirt) at an open exterior junction box

How it runs

The Wiring Follows the Spot

  1. 1

    Where the pad and the tub will sit

    That spot is fixed before any wire is chosen, since the run from the house, its length, and the breaker it needs all follow from it.

  2. 2

    The feed from the house

    The panel is checked for room, each circuit is sized to the equipment it serves, and the route from the back wall to the pad or the lanai is chosen, either run along the house wall or buried in conduit.

  3. 3

    Bonding and ground-fault protection

    The bond is tied to every metal part it has to reach, and ground-fault protection goes on the pool equipment and the outlets around the pool. On a pool that's already in, the existing bond connections are checked while the electrician is there, so new equipment joins a bond that's whole.

  4. 4

    Passed, then put to use

    The work is covered by a Pasco electrical permit, and Kennedy Electric files the application and schedules the county inspection once the wiring at the pad or lanai is in place. Only after it passes does the equipment or the tub go into use, with each ground-fault device tested on its first run.

What we cover

Where Each Pool Circuit Lands

At the back wall: The receptacles on the wall the lanai shares with the house, each given ground-fault protection, and the path the new feed takes as it leaves the house.

On the lanai, for a hot tub: A circuit that serves the tub alone, sized from the rating printed on the spa, with its disconnect placed where the lanai allows.

Under the screen roof: The pool light in its niche, its cord running up to a junction box mounted higher than the water, and LED lights on their transformer.

At the equipment pad: Every motor and controller there, from the pump to a salt chlorinator or an automation panel, wired to the figures on its own nameplate, with a disconnect at the pad for servicing.

Out toward the lot line: The buried run out to the pad, and power for a fountain or other water feature, on a circuit rated for outdoor use and protected against ground faults.

Pricing

Backyard Wiring Has No Set Price

01

How far the pad or lanai is from the panel, the equipment's label ratings, and whether the panel can accommodate new breakers all affect the price.

02

Repair and troubleshooting visits are billed by the hour from arrival: $100 residential, $150 commercial, one-hour minimum, then half-hour increments, plus materials. No trip charge and no service fee. No hidden fees: the 3.5% surcharge on card and ACH payments is listed in our terms.

03

We don't do upfront pricing. No job has a standard price with us: each one is tailored to the property and the work you've asked for, and priced once we've seen it.

We offer free estimates on installs, upgrades, and replacements in our service area. Estimates aren't free when the job needs troubleshooting or testing to price, falls after hours or outside our service area, needs several meetings to gather information, or is new construction or a custom remodel with multi-party walk-throughs. For most jobs, estimates arrive by email by the end of the next business day, and quotes are good for 30 days.

Our warranty

04

If something we installed fails because of our workmanship within 30 days of completion, we waive the hourly labor to put it right. Materials Kennedy Electric purchases for your job carry the manufacturer's one-year warranty. To replace defective materials we supplied, or materials damaged by storm, flood, fire, or other acts of God, we charge a reduced warranty labor rate of $50 an hour residential and $75 an hour commercial. The warranty does not cover materials not purchased by Kennedy Electric, work performed by the customer, or materials the customer purchased or damaged. Our warranty terms are printed on the estimate, the invoice, and the receipt, and the product boxes stay with you so you can register each product with its manufacturer.

Common questions

Close to the Water, Close to the House

Our Bayonet Point lanai is small. Where can a hardwired hot tub's disconnect go?

Somewhere in sight of the tub yet at least 5 feet from its inside wall. On a small lanai, those two limits can leave only one or two workable spots, so the disconnect's place is picked along with the tub's, before either goes in, with the tub's spec sheet in hand.

Our Bayonet Point pool sits inside an aluminum screen enclosure. Does the frame have to be bonded?

It may. Metal close to the water, such as an enclosure frame or a handrail, may need to join the pool's bond, depending on where it stands, and that's checked on site before the bond is tied in.

The new hot tub would sit on our Bayonet Point lanai next to an outlet that's already there. Can it plug in?

Only a 120-volt plug-and-play tub can, and not into an outlet that also feeds the lanai's lights or fan. It needs an outlet of its own with ground-fault protection, on a circuit that serves nothing else, placed where code puts it relative to the tub; a 240-volt tub is hardwired to its own breaker and disconnect.

Our pool pump and our house share one panel in the garage. Does the pad need its own subpanel?

Not always. A single pump on a circuit sized to its label can run straight from the house panel. When the pump, a heater, a chlorinator, and lighting all need to reach the pad, a subpanel there can carry them on a single feed, provided the house panel has the capacity.

An easement runs along the back of our lot. Does it affect where the pool wiring goes?

It can. The county wants easements drawn on the pool's site plan with their dimensions, so the pad and the buried run out to it are placed with that strip in view.

Reviews

Backyard Jobs, From the Homeowner's Side

Straight from Google, in our customers' own words.

Google reviews widget
Hands working on an open exterior junction box with colorful wires on green siding

Request service

What's Going In Out Back?

Tell us what's going in or what has stopped, and whether it sits on the lanai or out at the pad. Our office will reach you during business hours.

Kennedy Electric
1160 Ponce De Leon Blvd, Brooksville, FL 34601
Monday through Friday, 8 a.m. to 4 p.m.
Licensed & Insured · Florida Certified Electrical Contractor EC13011268
Serving Citrus, Hernando, and Pasco Counties, and nearby Sumter County.
Property type*
Best way to reach you*